Siemens
Kenxin Motors, a Siemens distributor, imports circuit breakers, electromagnetic contactors, and low-voltage power distribution equipment from Siemens, the German industrial giant founded in 1847. Kenxin Motors supplies 100% original Siemens certified switching control components to assist in building automated systems that comply with international safety regulations for smart manufacturing and energy management.
Read More
5SU1324-7FA10
The Siemens SENTRON 5SU1324-7FA10 is a 2-pole residual current circuit breaker with a rated current of 10A, a type A sensitivity of 30mA, a C-characteristic curve, and a short-circuit breaking capacity of 10kA. It is suitable for dual overcurrent and leakage protection applications in two-wire circuits.
Read More
5SU1324-7FA06
The Siemens SENTRON 5SU1324-7FA06 is a 2-pole residual current circuit breaker with a rated current of 6A, a type A sensitivity of 30mA, a C-characteristic curve, and a short-circuit breaking capacity of 10kA. It is suitable for overcurrent and leakage protection needs of control circuits or small loads.
Read More
5SU1324-6KX32
The Siemens SENTRON 5SU1324-6KX32 is a 2-pole residual current circuit breaker with a rated current of 32A, a rated voltage of 110V AC, and a short-circuit breaking capacity of 10kA. It belongs to the same series of B-characteristic curve 30mA type A products and is suitable for power distribution applications in specific voltage systems.
Read More
5SU1324-6KX25
The Siemens SENTRON 5SU1324-6KX25 is a 2-pole residual current circuit breaker with a rated current of 25A, a type A sensitivity of 30mA, a B characteristic curve, a rated voltage of 110V AC, and a short-circuit breaking capacity of 10kA. It is suitable for circuit protection in specific voltage systems.
Read More
5SU1324-6KX20
The Siemens SENTRON 5SU1324-6KX20 is a 2-pole residual current circuit breaker with a rated current of 20A, a type A sensitivity of 30mA, a characteristic curve of type B, and a short-circuit breaking capacity of 10kA. It is suitable for dual protection against overcurrent and leakage current in medium-sized load circuits.
Read More
5SU1324-6KX16
The Siemens SENTRON 5SU1324-6KX16 is a 2-pole residual current circuit breaker with a rated current of 16A, a type A sensitivity of 30mA, a B characteristic curve, a rated voltage of 110V AC, and a short-circuit breaking capacity of 10kA. It is suitable for circuit protection in specific voltage systems.
Read More
5SU1324-6KX06
The Siemens SENTRON 5SU1324-6KX06 is a 2-pole residual current circuit breaker with a rated current of 6A, a type A sensitivity of 30mA, a B characteristic curve, a rated voltage of 110V AC, and a short-circuit breaking capacity of 10kA. It is suitable for the protection of small-capacity specific voltage circuits.
Read More
5SU1324-6FA10
The Siemens SENTRON 5SU1324-6FA10 is a 2-pole residual current circuit breaker with a rated current of 10A, a type A sensitivity of 30mA, a characteristic curve of type B, and a short-circuit breaking capacity of 10kA. It is suitable for overcurrent and leakage protection in general lighting or socket circuits.
Read More
5SU1324-6FA20
The 5SU1324-6FA20 is a SENTRON 5SU1 series RCBO, 2-pole, rated current 20A, with a B characteristic curve, rated leakage current 30mA, and short-circuit breaking capacity 10kA. It is suitable for overload and leakage protection applications in residential and commercial distribution boxes.
Read More
5SU1323-1BB16
5SU1323-1BB16 belongs to the SENTRON 5SU1 series RCBO, 2 poles, rated current 16A, C-characteristic curve, rated leakage operating current 30mA, breaking capacity 4.5kA according to EN 61009-1, up to 15kA according to IEC 60947-2, suitable for general residential and commercial power distribution circuits.
Read More
5SU1323-1BB06
5SU1323-1BB06 is a SENTRON 5SU1 series RCBO, 2-pole, rated current 6A, C-characteristic curve, rated leakage current 30mA, breaking capacity 4.5kA according to EN 61009-1, suitable for overload and leakage protection requirements of small load circuits.
Read More
5SU1154-7KK06
5SU1154-7KK06 belongs to the SENTRON 5SU1 series RCBO, 1P+N, rated current 6A, C characteristic curve, rated leakage operating current 10mA, short circuit breaking capacity 10kA, suitable for applications requiring high leakage current sensitivity.
Read More
5SU1154-6KK13
5SU1154-6KK13 belongs to the SENTRON 5SU1 series RCBO, 1P+N, rated current 13A, B characteristic curve, rated leakage current 10mA, short circuit breaking capacity 10kA, suitable for high-sensitivity leakage protection in general residential circuits.
Read More
5SM6014-2
The 5SM6014-2 is a module of the SENTRON 5SM6 series AFDD arc fault detection device, with a rated current range of 1-40A. It is used with a 1P+N type MCB and is a non-leakage circuit breaker. Its main function is to detect sequential and parallel arcs to reduce the risk of electrical fires.