Procurement Zone
Read More
3RV2411-4AA10
SIRIUS 3RV2411-4AA10, S00 chassis thermal-magnetic circuit breaker, thermal overload adjustment range 10-16A, instantaneous short circuit trip 286A, screw terminals, original factory marking as transformer protection specification, made in Germany.
Read More
3RV2411-1KA10
SIRIUS 3RV2411-1KA10, S00 chassis thermal-magnetic circuit breaker, thermal overload adjustment range 9-12.5A, instantaneous short circuit trip 260A, screw terminals, original factory marking as transformer protection specification, made in Germany.
Read More
3RV2411-1JA20
SIRIUS 3RV2411-1JA20, S00 chassis thermal-magnetic circuit breaker, rated current 10A, 3 poles, Icu (400V) 100kA, original factory marking as transformer protection specification, made in Germany, RoHS compliant.
Read More
3RV2411-1JA15
SIRIUS 3RV2411-1JA15, S00 chassis thermal-magnetic circuit breaker, thermal overload adjustment range 7-10A, built-in 1 set of normally open and 1 set of normally closed auxiliary contacts, Icu (400V) 100kA, screw terminals, made in Germany.
Read More
3RV2411-1JA10
SIRIUS 3RV2411-1JA10, S00 chassis thermal-magnetic circuit breaker, thermal overload adjustment range 7-10A, instantaneous short circuit trip 208A, Icu (400V) 100kA, screw terminals, auxiliary contacts not included, made in Germany.
Read More
3RV2411-1HA15
The 3RV2411-1HA15 is a Siemens SIRIUS 3RV2 series S00 size thermal-magnetic circuit breaker, combining thermal overload and electromagnetic instantaneous tripping dual protection. It has a current setting range of 5.5-8A, a short-circuit release value of 163A, and a screw terminal design, making it suitable for transformer circuit overload and short-circuit protection. Kenxin Motor has stock available and provides selection consultation.
Read More
3RV2411-1HA10
The 3RV2411-1HA10 is a Siemens SIRIUS 3RV2 series S00 size thermal-magnetic circuit breaker, combining thermal overload and electromagnetic instantaneous tripping dual protection. It has a current setting range of 5.5-8A, a short-circuit release value of 163A, and a screw terminal design, making it suitable for transformer circuit overload and short-circuit protection. Kenxin Motor has stock available and provides selection consultation.
Read More
3RV2411-1GA20
The 3RV2411-1GA20 is a Siemens SIRIUS 3RV2 series S00 size thermal-magnetic circuit breaker, combining thermal overload and electromagnetic instantaneous tripping dual protection. It has a current setting range of 4.5-6.3A, a short-circuit release value of 130A, and a spring-loaded terminal design, making it suitable for transformer circuit overload and short-circuit protection. Kenxin Motor has stock available and provides selection consultation.
Read More
3RV2411-1GA10
The 3RV2411-1GA10 is a Siemens SIRIUS 3RV2 series S00 size thermal-magnetic circuit breaker, combining thermal overload and electromagnetic instantaneous tripping dual protection. It has a current setting range of 4.5-6.3A, a short-circuit release value of 130A, and a screw terminal design, making it suitable for transformer circuit overload and short-circuit protection. Kenxin Motor has stock available and provides selection consultation.
Read More
3RV2411-1FA20
The 3RV2411-1FA20 is a Siemens SIRIUS 3RV2 series S00 size thermal-magnetic circuit breaker, combining thermal overload and electromagnetic instantaneous tripping dual protection. It has a current setting range of 3.5-5A, a short-circuit release value of 104A, and a spring-loaded terminal design, making it suitable for transformer circuit overload and short-circuit protection. Kenxin Motor has stock available and provides selection consultation.
Read More
3RV2411-1FA15
The 3RV2411-1FA15 is a Siemens SIRIUS 3RV2 series S00 size thermal-magnetic circuit breaker, combining thermal overload and electromagnetic instantaneous tripping dual protection. It has a current setting range of 3.5-5A, a short-circuit release value of 104A, and a screw terminal design, making it suitable for transformer circuit overload and short-circuit protection. Kenxin Motor has stock available and provides selection consultation.
Read More
3RV2411-1FA10
The 3RV2411-1FA10 is a Siemens SIRIUS 3RV2 series S00 size thermal-magnetic circuit breaker, combining thermal overload and electromagnetic instantaneous tripping dual protection. It has a current setting range of 3.5-5A, a short-circuit release value of 104A, and a screw terminal design, making it suitable for transformer circuit overload and short-circuit protection. Kenxin Motor has stock available and provides selection consultation.
Read More
3RV2411-1EA20
The 3RV2411-1EA20 is a Siemens SIRIUS 3RV2 series S00 size thermal-magnetic circuit breaker, combining thermal overload and electromagnetic instantaneous tripping dual protection. It has a current setting range of 2.8-4A, a short-circuit release value of 82A, and a spring-loaded terminal design, making it suitable for transformer circuit overload and short-circuit protection. Kenxin Motor has stock available and provides selection consultation.
Read More
3RV2411-1EA15
The 3RV2411-1EA15 is a Siemens SIRIUS 3RV2 series S00 size thermal-magnetic circuit breaker, combining thermal overload and electromagnetic instantaneous tripping dual protection. It has a current setting range of 2.8-4A, a short-circuit release value of 82A, and a screw terminal design, making it suitable for transformer circuit overload and short-circuit protection. Kenxin Motor has stock available and provides selection consultation.
Read More
3RV2411-1EA10
The 3RV2411-1EA10 is a Siemens SIRIUS 3RV2 series S00 size thermal-magnetic circuit breaker, combining thermal overload and electromagnetic instantaneous tripping dual protection. It has a current setting range of 2.8-4A, a short-circuit release value of 82A, and a screw terminal design, making it suitable for transformer circuit overload and short-circuit protection. Kenxin Motor has stock available and provides selection consultation.