3RV2411-1DA20
The 3RV2411-1DA20 is a SIRIUS 3RV2411 series S00 size circuit breaker with a current setting of 2.2~3.2A, a fixed short-circuit trip of 65A, a rated insulation voltage of 690V AC, and is suitable for transformer circuit protection. It uses spring-loaded (screwless) terminals, is manufactured in Germany, and complies with RoHS regulations.
Read More
3RV2411-1DA15
The 3RV2411-1DA15 is a SIRIUS 3RV2411 series S00 size circuit breaker with a current setting of 2.2~3.2A, a fixed short-circuit trip of 65A, a rated insulation voltage of 690V AC, and is suitable for transformer circuit protection. It uses screw-type terminals, is manufactured in Germany, and complies with RoHS regulations.
Read More
3RV2411-1DA10
The 3RV2411-1DA10 is a SIRIUS 3RV2411 series S00 size circuit breaker with a current setting of 2.2~3.2A, a fixed short-circuit trip of 65A, a rated insulation voltage of 690V AC, and is suitable for transformer circuit protection. It uses screw-type terminals, is manufactured in Germany, and complies with RoHS regulations.
Read More
3RV2411-1CA20
The 3RV2411-1CA20 is a SIRIUS 3RV2411 series S00 size circuit breaker with a current setting of 1.8~2.5A, a fixed short-circuit trip of 52A, a rated insulation voltage of 690V AC, and is suitable for transformer circuit protection. It uses spring-loaded (screwless) terminals, is manufactured in Germany, and complies with RoHS regulations.
Read More
3RV2411-1CA10
The 3RV2411-1CA10 is a SIRIUS 3RV2411 series S00 size circuit breaker with a current setting of 1.8~2.5A, a fixed short-circuit trip of 52A, a rated insulation voltage of 690V AC, and is suitable for transformer circuit protection. It uses screw-type terminals, is manufactured in Germany, and complies with RoHS regulations.
Read More
3RV2411-1BA20
The 3RV2411-1BA20 is a SIRIUS 3RV2411 series S00 size circuit breaker with a current setting of 1.4~2A, a fixed short-circuit trip of 42A, a rated insulation voltage of 690V AC, and is suitable for transformer circuit protection. It uses spring-loaded (screwless) terminals, is manufactured in Germany, and complies with RoHS regulations.
Read More
3RV2411-1BA10
The 3RV2411-1BA10 is a SIRIUS 3RV2411 series S00 size circuit breaker with a current setting of 1.4~2A, a fixed short-circuit trip of 42A, a rated insulation voltage of 690V AC, and is suitable for transformer circuit protection. It uses screw-type terminals, is manufactured in Germany, and complies with RoHS regulations.
Read More
3RV2411-1AA10
The 3RV2411-1AA10 is a SIRIUS 3RV2411 series S00 size circuit breaker with a current setting of 1.1~1.6A, a fixed short-circuit trip of 33A, a rated insulation voltage of 690V AC, suitable for transformer circuit protection, and uses screw-type terminals. It is manufactured in Germany and complies with RoHS regulations.
Read More
3RV2411-0KA10
The 3RV2411-0KA10 is a SIRIUS 3RV2411 series S00 size circuit breaker with a current setting of 0.9~1.25A, a fixed short-circuit trip of 26A, a rated insulation voltage of 690V AC, and is suitable for transformer circuit protection. It uses screw-type terminals, is manufactured in Germany, and complies with RoHS regulations.
Read More
3RV2411-0JA20
The 3RV2411-0JA20 is a SIRIUS 3RV2411 series S00 size circuit breaker with a current setting of 0.7~1A, a fixed short-circuit trip of 21A, a rated insulation voltage of 690V AC, and is suitable for transformer circuit protection. It uses spring-loaded (screwless) terminals, is manufactured in Germany, and complies with RoHS regulations.
Read More
3RV2411-0JA10
The 3RV2411-0JA10 is a SIRIUS 3RV2 S00 series thermal-magnetic circuit breaker with a current setting range of 0.7...1 A, a short-circuit instantaneous trip value of 21 A, and screw terminals. It is specifically designed for overload and short-circuit protection on the secondary side of small transformers. Kenxin Motor is an authorized Siemens distributor, providing genuine original products and technical consultation.
Read More
3RV2411-0HA20
The 3RV2411-0HA20 is a SIRIUS 3RV2 S00 series thermal-magnetic circuit breaker with a current setting range of 0.55...0.8 A and a short-circuit instantaneous trip value of 16 A. It uses spring terminals and is specifically designed for overload and short-circuit protection on the secondary side of small transformers. Kenxin Motor is an authorized Siemens distributor, providing genuine original products and technical consultation.
Read More
3RV2411-0HA10
The 3RV2411-0HA10 is a SIRIUS 3RV2 S00 series thermal-magnetic circuit breaker with a current setting range of 0.55...0.8 A. It uses screw terminals and is specifically designed for overload and short-circuit protection on the secondary side of small transformers. Kenxin Motor is an authorized Siemens distributor, providing genuine original products and technical consultation.
Read More
3RV2411-0GA10
The 3RV2411-0GA10 is a SIRIUS 3RV2 S00 series thermal-magnetic circuit breaker with a current setting range of 0.45...0.63 A, a short-circuit instantaneous trip value of 13 A, and screw terminals. It is specifically designed for overload and short-circuit protection on the secondary side of small transformers. Kenxin Motor is an authorized Siemens distributor, providing genuine original products and technical consultation.
Read More
3RV2411-0FA10
The 3RV2411-0FA10 is a SIRIUS 3RV2 S00 series thermal-magnetic circuit breaker with a current setting range of 0.35...0.5 A, a short-circuit instantaneous trip value of 10 A, and screw terminals. It is specifically designed for overload and short-circuit protection on the secondary side of small transformers. Kenxin Motor is an authorized Siemens distributor, providing genuine original products and technical consultation.